The SDS011 Air Quality Sensor experiment
Real-time Air Quality readings from the SDS011

بانٹیں: aqicn.org/sensor/sds011/ur/

For a complete list of all the Air Quality Sensors test on the World Air Quality Index project, check our sensor overview page.


The SDS 011 Sensor

The SDS 011 Sensor is a quite recent Air Quality Sensor developed by Nova Fitness, a spin-off from the university of Jinan (in Shandong).

With its size, it is probably one of the best sensor in terms of accuracy: While other sensors tend to focus on shrinking the sensor size, the SDS 011 has opted for a size tradeoff allowing it to use a larger fan. And the larger the fan, the better the quality.

Specifications

Spec sheet: SDS011-datasheet-v1.3

This is the specification for the SDS011. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).

  • Output: PM2.5, PM10
  • Measuring Range: 0.0-999.9μg/m3
  • Input Voltage:5V
  • Maximum Current: 100mA
  • Sleep Current: 2mA
  • Response Time 1 second
  • Serial Data Output Frequency: 1 time/second
  • Particle Diameter Resolution: ≤0.3μm
  • Relative Error:10%
  • Temperature Range:-20~50°C
  • Physical Size: 71mm*70mm*23mm

Note that the SDS011 humidity working range is 0-70%. This is so good, since above 70% humidity, the readings become unrealiable.

Inside look at the sensor

The clever engineering in the SD011 is to use the PCB as one side of the casing (allowing to reduce the BOM cost). The diode is mounted on the PCB side (this is mandatory as any noise between the doide and the LNA should be avoided). The laser mounted on the plastic box and connected to the PCB via flying wire.

The biggest problem of this design is that the entire sensor inside is getting very dusty, as shown on the picture below after running 24/7 for more than 6 months. This is actually not so bad since the dust did not get accumulated on the diode, nor on the laser frontend. As concern the fan, dust accumulation is a "normal behavior" also seen on the dylos.

Last, as concerns the PCB, is it quite simple. The main CPU is an 8bit processor (scratched to prevent from beeing reversed engineered!). Under the shielding one can find the Low Noise Amplifier (directly mounted on the opposite side of the diode).

Experiment Setup

There are two SDS011 colocated. The SDS011i #1 is a sensor which has been used outdoor for several months. The SDS011 #2 is a brand new sensor (from Sept. 2016).

Real-time data

Current BAM readings are:
  • PM2.5 mass in mg/m3 -,
  • updated on - - (China time).
First SDS011i #1 (old) readings are:
  • PM2.5 mass in mg/m3 -,
  • PM10 mass in mg/m3 -,
  • updated on - - (China time).
Second SDS011i #2 (new) readings are:
  • PM2.5 mass in mg/m3 -,
  • PM10 mass in mg/m3 -,
  • updated on - - (China time).

Comparison with Official BAM readings

PM2.5 based Air quality data:




PM10 based Air quality data:






- -

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

ہوا کے معیار اور آلودگی کی پیمائش کے بارے میں:

ہوا کے معیار کی سطح کے بارے میں

- ایئر کوالٹی انڈیکس (AQI) اقدارصحت کی تشویش کی سطح
0 - 50 اچھی ہوا کے معیار کو تسلی بخش سمجھا جاتا ہے، اور ہوا آلودگی سے کم یا کوئی خطرہ ہوتا ہے
51 -100 معتدل فضائی معیار قابل قبول ہے؛ تاہم، بعض آلودگیوں کے لئے وہاں بہت کم تعداد میں لوگوں کے لئے اعتدال پسند صحت کی تشویش ہو سکتی ہے جو فضائی آلودگی سے غیر معمولی حساس ہیں.
101-150 حساس افراد کیلئے غیر صحتمند حساس گروپوں کے ارکان صحت کے اثرات کا تجربہ کرسکتے ہیں. عام عوام کو متاثر نہیں ہونے کا امکان ہے.
151-200 مضر صحت ہر کوئی صحت کے اثرات کا سامنا کرنا شروع کر سکتا ہے؛ حساس گروہوں کے ارکان زیادہ سنجیدہ صحت کے اثرات کا تجربہ کرسکتے ہیں
201-300 انتہائی مضر صحت انتباہ صحت برائے ہنگامی حالات. پوری آبادی متاثر ہونے کا امکان ہے
300+ خطرناک صحت کی انتباہ: ہر ایک کی صحت کو زیادہ سنگین اثرات کا سامنا کر نا پڑ سکتا ہے

ہوا کے معیار اور آلودگی کے بارے میں مزید جاننے کے لیے، ویکیپیڈیا ایئر کوالٹی کا موضوع یا ایئر کوالٹی اور آپ کی صحت کے لیے ایئرنو گائیڈ دیکھیں۔

بیجنگ کے ڈاکٹر رچرڈ سینٹ سائر ایم ڈی کے صحت سے متعلق بہت مفید مشوروں کے لیے، www.myhealthbeijing.com بلاگ دیکھیں۔


استعمال کی اطلاع: اشاعت کے وقت تمام ایئر کوالٹی کے اعداد وشمار غیرتصدیق شدہ ھیں ، اور معیار کی یقین دہانی کے باعث ان اعداد و شمار کو بغیراطلاع ترمیم کیا جا سکتا ہے، کسی نوٹس کے بغیر. ورلڈ ایئر کوالٹی انڈیکس نے اس معلومات کے مضامین کو مرتب کرنے میں تمام معقول مہارت اور دیکھ بھال کا استعمال کیا ہے اور کسی بھی حالت میں نہیں ورلڈ ایئر کوالٹی انڈیکس پروجیکٹ ٹیم یا اس کے ایجنٹوں کو اس ڈیٹا کی فراہمی سے براہ راست یا غیر مستقیم طور پر پیدا کسی بھی نقصان، چوٹ یا نقصان کے لئے معاہدے، تشدد یا دوسری صورت میں ذمہ دار ہوسکتا ہے.



Settings


Language Settings:


Temperature unit:
Celcius