The SDS011 Air Quality Sensor experiment
Real-time Air Quality readings from the SDS011

Share: aqicn.org/sensor/sds011/kr/
For a complete list of all the Air Quality Sensors test on the World Air Quality Index project, check our sensor overview page.

The SDS 011 Sensor

The SDS 011 Sensor is a quite recent Air Quality Sensor developed by inovafit, a spin-off from the university of Jinan (in Shandong).

With its size, it is probably one of the best sensor in terms of accuracy: While other sensors tend to focus on shrinking the sensor size, the SDS 011 has opted for a size tradeoff allowing it to use a larger fan. And the larger the fan, the better the quality.

Specifications

This is the specification for the SDS011. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).
  • Output: PM2.5, PM10
  • Measuring Range: 0.0-999.9μg/m3
  • Input Voltage:5V
  • Maximum Current: 100mA
  • Sleep Current:2mA
  • Response Time1 second
  • Serial Data Output Frequency: 1 time/second
  • Particle Diameter Resolution:≤0.3μm
  • Relative Error:10%
  • Temperature Range:-20~50°C
  • Physical Size: 71mm*70mm*23mm

Inside look at the sensor

The clever engineering in the SD011 is to use the PCB as one side of the casing (allowing to reduce the BOM cost). The diode is mounted on the PCB side (this is mandatory as any noise between the doide and the LNA should be avoided). The laser mounted on the plastic box and connected to the PCB via flying wire.
The biggest problem of this design is that the entire sensor inside is getting very dusty, as shown on the picture below after running 24/7 for more than 6 months. This is actually not so bad since the dust did not get accumulated on the diode, nor on the laser frontend. As concern the fan, dust accumulation is a "normal behavior" also seen on the dylos.
Last, as concerns the PCB, is it quite simple. The main CPU is an 8bit processor (scratched to prevent from beeing reversed engineered!). Under the shielding one can find the Low Noise Amplifier (directly mounted on the opposite side of the diode).

Experiment Setup

There are two SDS011 colocated. The SDS011i #1 is a sensor which has been used outdoor for several months. The SDS011 #2 is a brand new sensor (from Sept. 2016).

Real-time data

Current BAM readings are:
  • PM2.5 mass in mg/m3 -,
  • updated on - - (China time).
First SDS011i #1 (old) readings are:
  • PM2.5 mass in mg/m3 -,
  • PM10 mass in mg/m3 -,
  • updated on - - (China time).
Second SDS011i #2 (new) readings are:
  • PM2.5 mass in mg/m3 -,
  • PM10 mass in mg/m3 -,
  • updated on - - (China time).

Comparison with Official BAM readings

PM2.5 based Air quality data:
PM10 based Air quality data:




--

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

대기질 및 환경 오염 측정에 관하여 :

대기질 지수 단계에 대하여

AQI지수구분구간의미
0 - 50 좋음 대기오염 관련 질환자군에서도 영향이 유발되지 않을 수준
51 -100 보통 환자군에게 만성 노출시 경미한 영향이 유발될 수 있는 수준
101-150 민감군영향 환자군 및 민감군에게 유해한 영향이 유발될 수 있는 수준
151-200 나쁨 환자군 및 민감군(어린이, 노약자 등)에게 유해한 영향 유발, 일반인도 건강상 불쾌감을 경험할 수 있는 수준
201-300 매우나쁨 환자군 및 민감군에게 급성 노출시 심각한 영향 유발, 일반인도 약한 영향이 유발될 수 있는 수준
300+ 위험 환자군 및 민감군에게 응급 조치가 발생되거나, 일반인에게 유해한 영향이 유발될 수 있는 수준
(Reference: see airkorea.or.kr)

대기질과 오염에 대해 더 많은 것을 알아보려면 위키피디아의 대기질 문서(영어)을 보거나 대기질과 건강에 대한 AirNow 가이드(영어)를 참조해보세요.

매우 유용한 베이징의 의학박사 Richard Saint Cyr MD의 건강 관련 팁을 보려면 www.myhealthbeijing.com 의 블로그를 확인하세요.


사용안내: 모든 대기 질 데이터는 발행 당시에 검증되지 않았으며, 품질 보증으로 인해 이러한 데이터는 예고없이 언제든지 수정 될 수 있습니다. 세계 대기 품질 지수 프로젝트는이 정보의 내용을 편집함에있어 합당한 기술과 관심을 행사했으며 어떤 상황에서도 세계 대기 품질 지수 (World Air Quality Index) 프로젝트 팀 또는 그 대리인은이 데이터의 공급으로 인해 직접 또는 간접적으로 발생하는 손실, 상해 또는 손해에 대해 계약, 불법 행위 또는 기타의 책임을지지 않습니다.



설정


언어 설정 :


Temperature unit:
Celcius