Ozone AQI: Using concentrations in milligrams or ppb?

Posted on September 6th 2015
Podíl: aqicn.org/faq/2015-09-06/ozone-aqi-using-concentrations-in-milligrams-or-ppb/cs/

The ambient Ozone, refered as O3 and also called called ground-level or tropospheric Ozone impacts everyone on earth regardless of the country, as shown on the image on the right [1].

Afternoon ground level Ozone concentration in July 2011

(Attribution: WMO GAW research on reactive gases )

Unlike particulate matter (PM2.5), the ground-level Ozone is not emitted directly. It is instead produced through a series of chemical reactions that occur in presence of nitrogen oxides, volatile organic compounds, sunlight and high temperatures, as shown on the following visual:

Quantifying the impact of this ground level Ozone on Health is done via the Air Quality Index standard which each country defines. What is interesting is that half of the world is using a standard based on milligrams measurement, while the rest is using ppb based measurement. But is this really a problem? This is what we will be looking at in this article.


--

The US EPA standard for Ozone is based on ppm, while the European one are based on milligrams.

So, we naturally targetted our question to Environnement S.A, one of the leading European enviromental equipment manufacturer, who develops its own O342M Ozone analyser (see picture on the right).

The O342M is both both certified by the US EPA and the EU (see specsheet), therefore able to provide measurement in both ppm and milligrams. Our question to Environnement S.A was 'How does your ozone analyser support both ppm and milligrams output? Is there any hardware difference for measurement? If not, is there any standard for the convertion?'.

Ozone Measurement Principles

The ozone measurement is based on the universally known UV absorption principle [2], which consists in measuring UV absorption of ozone molecules. Ozone concentration is determined by difference between UV absorption of the gas sample and the sample without ozone after filtration performed by a catalytic converter.

In this system, the Ozone concentration is measured as an amount of light energy per volume of air, from which the concentration in ppbv is deducted. The lower detectable limit for this system is 0.4 ppb (corresponding to an AQI of 0.3, based on the US EPA 8-hour Ozone standard). This system does not measure the mass as such, but there is a standard way of doing the convertion from ppmv to mg/m3.

Converting Atmospheric Pollutant Concentrations: from ppmv to mg/m3

First, ppm (parts per million [3] ) and ppb (parts per billion) are defined as `1 ppm = 1/106 = 10-6` and `1 ppb = 1/109 = 10-9`. So `1 ppm = 1000 ppb or 1 ppb = 10-3 ppm`.

The conversion factor depends on the temperature at which you want the conversion (usually 25 degrees Centigrade in the US), as well as the ambient pressure. At an ambient pressure of 1 atmosphere, the general equation is:

$$c = { ppmv \times 12.187 \times MW \over 273.15 + t } $$
where:
  • c = concentration in mg/m3(i.e., milligrams of gaseous pollutant per cubic meter of ambient air)
  • MW = molecular weight of the gaseous pollutant
  • ppmv = parts per million by volume (i.e., volume of gaseous pollutant per million volumes of ambient air)
  • t = ambient temperature in degrees centigrade.
  • 12.187 = inverse of the Universal Gas Law constant[4]

As an example, for gaseous pollutant O3 (ozone), to convert 20 ppmv of Ozone to `mg/m3 at 25 °C` and 1 atmosphere, the following formula is used:

$$ c(20 ppmv) = { 20 \times 12.187 \times 48 \over 273.15 + 25 } = {20 \times 1.97} = 39.4 mg/m^3$$
where: 48.00 = `MW(O3)` = molecular weight of Ozone O3.

European and US Convertion Standards

The assumption on the ambient temperature and atmospheric pressure is actually standardized and summurized in the following table for US, Europe or normal conditions. For our O342M Ozone analyzers, this coefficient is user programmable by the operator of the instrument.

Gas Standard Conditions for Temperature and Pressure ( STP)
"STP US" Conditions at 25°C
(US EPA standard) [5]
1013 mbar and 298K
"STP European Union" Conditions at 20°C
(EU standard) [6]
1013 mbar and 293K
"Normal" Conditions at 0°C
1013 mbar and 273K
O3 - Ozone 1 ppb = `1,97` µg/m3 1 ppb = `2,00` µg/m3 1 ppb = `2,15` µg/m3
NO2 - Nitrogen Dioxyde 1 ppb = `1,88` µg/m3 1 ppb = `1,91` µg/m3 1 ppb = `2,05` µg/m3

Note: For those interested in knowing why 20°C is used as the standard reference temperature, you can check Ted Doiron's article on "20 °C—A short history of the standard reference temperature for industrial dimensional measurements".

Many thanks to Serge from Environnement S.A for the quick and precise answer on the Ozone monitors. Note that the same concept also applies to other gases such as Nitrogen Dioxide (for instance using the AS32M analyser).


--

To push the investigation a bit further, the next question is what would be the impact on the calculated Air Quality Index if the actual temperature and pressure would be used instead of the reference one?

Impact from ambient temperature

The last question is to look at the impact of a temperature variation on the Air Quality Index.

For instance, let assume that an instrument is measuring an average of `120 mg/m3` of Ozone over 1 hour, which corresponds to an AQI of 50 (Medium) according to the European Common Air Quality Index (CAQI).

At 20°C and 1 atm, `120 mg/m^3` converts to 120/2.00, i.e. 60.0 ppmv. So let us assume that this is the actual measurement from the Ozone sensor. The question is then, what if the ambient temperature was peaking to 42°C, as it sometimes happen during summer heat waves, then what would be the correct mass? The convertion formula is:



$$c = { ppmv \times 12.187 \times MW \over 273.15 + t } = 111.37 $$

This results in a difference of `8.6 mg/m^3` of measured Ozone. When applying the CAQI standard, the corresponding AQI is 46.4 (instead of 50 using the standard 20°C condition). This is actually an acceptable difference.

The generalized adjustement formula depending on the ambient temperature is summurized with the graph on the right. The x-axis is the ambient temperature, and the y-axis the calculated AQI is the actual temperature would be used instead of the reference one (20°C).

Impact from atmospheric pressure

As concerns the atmospheric pressure, the varation is defined by the Ideal Gas Law (`PV = nRT`).

The value 12.187 is actually the inverse of the Universal Gas Law constant R. So, to understand the impact of atmospheric pressure, the following formula can be used:

$$R = {{ P \times V } \over {n \times T}} = {{ P \times 22.4 } \over { 1 \times 273 }} = { P \over 12.1875 } $$

In other words, one just need to divide the convertion factor by the current atmosphere. Assuming that the pressure p is expressed in millibars (1 atm = 1013.25 mb), the generalized convertion formula becomes:

$$c = { ppmv \times MW \times 1013.25 \times 12.1875 \over { p \times (273.15 + t)} } $$
where:
  • c = concentration in mg/m3(i.e., milligrams of gaseous pollutant per cubic meter of ambient air)
  • MW = molecular weight of the gaseous pollutant
  • ppmv = parts per million by volume (i.e., volume of gaseous pollutant per million volumes of ambient air)
  • t = ambient temperature in degrees centigrade.
  • p = ambient atmospheric pressure in millibars.

Conclusions

The above explanations confirm our initial hypothesis that even though Ozone readings can be provided with different units (ppm and `mg/m^3`), this is actually not a problem since there is a standard way to convert readings from `mg/m^3 to ppm` and vice-versa. Moreover, the impact of using the reference STP (Standard Temperature & Pressure) instead of the actual ambient temperature and pressure is minimal, i.e. just units of Index in difference for the Ozone.



Credits: Ozone visual recreated using Icon pack by Icons8 and taken from American Chemical Society.

[1] This Ozone is not to be confused with the good ozone also called stratospheric ozone
[3] Parts per million also can be expressed as milligrams per liter (mg/L). This measurement is the mass of a chemical or contaminate per unit volume of water. Seeing ppm or mg/L on a lab report means the same thing. from University of Minnesota
[4] https://en.wikipedia.org/wiki/Gas_constant
Click here to see all the FAQ entries
  • AQI Scale: What do the colors and numbers mean?
  • Using Statistical Distances for Real-time Sensor Networks Validation
  • Nitrogen Dioxyde (NO2) in our atmosphere
  • O měření kvality ovzduší a znečištění:

    O úrovních kvality ovzduší

    -Hodnoty indexu kvality ovzduší (AQI).Úrovně obav o zdraví
    0 - 50DobrýKvalita ovzduší je považována za uspokojivou a znečištění ovzduší představuje malé nebo žádné riziko
    51 -100MírnýKvalita ovzduší je přijatelná; u některých znečišťujících látek však může existovat mírný zdravotní problém u velmi malého počtu lidí, kteří jsou neobvykle citliví na znečištění ovzduší.
    101-150Nezdravé pro citlivé skupinyČlenové citlivých skupin mohou mít účinky na zdraví. Obecná veřejnost pravděpodobně nebude zasažena.
    151-200NezdravýKaždý může začít projevovat účinky na zdraví. členové citlivých skupin mohou mít vážnější účinky na zdraví
    201-300Velmi NezdravéZdravotní varování při havarijních podmínkách. Celá populace je pravděpodobněji postižena.
    300+NebezpečnýZdravotní upozornění: každý může mít vážnější zdravotní účinky

    Chcete-li se dozvědět více o kvalitě ovzduší a znečištění, podívejte se na téma Kvalita ovzduší na wikipedii nebo na airnow průvodce Kvalita ovzduší a vaše zdraví .

    Velmi užitečné zdravotní rady pekingského lékaře Richarda Saint Cyr MD najdete na blogu www.myhealthbeijing.com .


    Upozornění na použití: Veškeré údaje o kvalitě ovzduší jsou v době zveřejnění neplatné a vzhledem k zajištění kvality mohou být tyto údaje kdykoli změněny bez upozornění. Projekt Světový index kvality ovzduší vynaložil veškeré přiměřené schopnosti a péči při sestavování obsahu těchto informací a za žádných okolností Projektový tým Světového indexu kvality ovzduší nebo jeho zástupci nesou odpovědnost za smluvní, delikt nebo jinou odpovědnost za jakoukoliv ztrátu, zranění nebo škodu vzniklou přímo nebo nepřímo z poskytování těchto údajů.



    Settings


    Language Settings:


    Temperature unit:
    Celcius