The Plantower PMS1003 Air Quality Sensor experiment
Real-time Air Quality readings from the PMS1003

공유하다: aqicn.org/sensor/pms1003/kr/
For a complete list of all the Air Quality Sensors test on aqicn.org, check our sensor overview page.

The PMS 1003 Sensor

The PMS 1003 Sensor is a recent laser based Air Quality Sensor developped by plantower (chinese name: 攀藤 (pānténg)) and used inside a numerous number of air quality sensing devices.

It is also sometimes refered as HK 5001, or labelled under the "oneair" brand, but it is indeed developped and produced by plantower (a Shenzhen based company with office in Beijing).

명세서

This is the specification for the PMS1003. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).
  • Measuring range: 0.3 to 1.0, 1.0 ~ 2.5, 2.5 to 10 microns (um)
  • Range: 0 ~ 500 ug / m3
  • counting accuracy of 50% @ 0.3um, 98% @ ≥0.5 um said the quasi-volume : 0.1 liters (L)
  • Response time: ≤10 seconds (s)
  • DC supply voltage: 5.0 volts (V)
  • Maximum Operating Current: 120 milliamperes (mA)
  • Standby current: ≤200 microamps (uA)
  • Operating temperature range: -20 ~ + 50 degrees Celsius (℃)
  • Operating humidity range: 0 ~ 99% RH
  • MTBF: ≥ 5 years (Y)
  • Maximum size: 65 × 42 × 23 mm
Note that there are more recent sensors from plantower (PMSxxxx series) which we will be testing later.

센서 내부 살펴보기

The sensor comes with a metal casing which is used to prevent from electrostatic discharge (ESD). The inside is enginered like a small dylos monitor:
Image attribution: geek-workshop.com.

- -

In terms of electronics, the PMS1003 is simple but yet very efficient. The main CPU is a Cypress CY8C4245, which a combined ARM Cortex-M0 running at 48Mhz with dedicated ADC, used to sample the output from the diode.

In terms of dust accumulation, the situation is actually not so bad since after 6 months running 24/7, the dust would only accumulated next to the air inlet, but not on the diode or laser.

실시간 데이터

Note: The sensor has been replaced with a new sensor on Nov. 6th 2015. We suspect that the old sensor, which was used 24/7 during 1 hour (in outdoor conditions) is not accurate anymore, either due to dust accumulation, or to decreased sensitivity of the diode to laser power. Once we have more information about this issue, we will provide our findings.

Current Dylos readings are:
  • Particules larger than 2.5 is -,
  • Particules llarger than 0.5 is -,
  • updated on - - (China time).

Current PMS1003 readings:
  • PM1 mg/m3: -,
  • PM2.5 mg/m3: -,
  • PM10 mg/m3: -,
  • updated on - - (China time).

Time series graphs

Note that on the above graph, each of the graph is plotted using a loess smoothing since the output from the PMS 1003 is quite noisy. You can move your mouse over the graph labels to see the actual output vs. the averaged values.

PM2.5 Comparison with Dylos

PM10 Comparison with Dylos




- -

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

대기질 및 환경 오염 측정에 관하여 :

대기질 지수 단계에 대하여

AQI지수구분구간의미
0 - 50 좋음 대기오염 관련 질환자군에서도 영향이 유발되지 않을 수준
51 -100 보통 환자군에게 만성 노출시 경미한 영향이 유발될 수 있는 수준
101-150 민감군영향 환자군 및 민감군에게 유해한 영향이 유발될 수 있는 수준
151-200 나쁨 환자군 및 민감군(어린이, 노약자 등)에게 유해한 영향 유발, 일반인도 건강상 불쾌감을 경험할 수 있는 수준
201-300 매우나쁨 환자군 및 민감군에게 급성 노출시 심각한 영향 유발, 일반인도 약한 영향이 유발될 수 있는 수준
300+ 위험 환자군 및 민감군에게 응급 조치가 발생되거나, 일반인에게 유해한 영향이 유발될 수 있는 수준
(Reference: see airkorea.or.kr)

대기질과 오염에 대해 더 많은 것을 알아보려면 위키피디아의 대기질 문서(영어)을 보거나 대기질과 건강에 대한 AirNow 가이드(영어)를 참조해보세요.

매우 유용한 베이징의 의학박사 Richard Saint Cyr MD의 건강 관련 팁을 보려면 www.myhealthbeijing.com 의 블로그를 확인하세요.


사용안내: 모든 대기 질 데이터는 발행 당시에 검증되지 않았으며, 품질 보증으로 인해 이러한 데이터는 예고없이 언제든지 수정 될 수 있습니다. 세계 대기 품질 지수 프로젝트는이 정보의 내용을 편집함에있어 합당한 기술과 관심을 행사했으며 어떤 상황에서도 세계 대기 품질 지수 (World Air Quality Index) 프로젝트 팀 또는 그 대리인은이 데이터의 공급으로 인해 직접 또는 간접적으로 발생하는 손실, 상해 또는 손해에 대해 계약, 불법 행위 또는 기타의 책임을지지 않습니다.



설정


언어 설정 :


Temperature unit:
Celcius