The Plantower PMS1003 Air Quality Sensor experiment
Real-time Air Quality readings from the PMS1003

Aktie: aqicn.org/sensor/pms1003/de/
For a complete list of all the Air Quality Sensors test on aqicn.org, check our sensor overview page.

The PMS 1003 Sensor

The PMS 1003 Sensor is a recent laser based Air Quality Sensor developped by plantower (chinese name: 攀藤 (pānténg)) and used inside a numerous number of air quality sensing devices.

It is also sometimes refered as HK 5001, or labelled under the "oneair" brand, but it is indeed developped and produced by plantower (a Shenzhen based company with office in Beijing).

Spezifikationen

This is the specification for the PMS1003. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).
  • Measuring range: 0.3 to 1.0, 1.0 ~ 2.5, 2.5 to 10 microns (um)
  • Range: 0 ~ 500 ug / m3
  • counting accuracy of 50% @ 0.3um, 98% @ ≥0.5 um said the quasi-volume : 0.1 liters (L)
  • Response time: ≤10 seconds (s)
  • DC supply voltage: 5.0 volts (V)
  • Maximum Operating Current: 120 milliamperes (mA)
  • Standby current: ≤200 microamps (uA)
  • Operating temperature range: -20 ~ + 50 degrees Celsius (℃)
  • Operating humidity range: 0 ~ 99% RH
  • MTBF: ≥ 5 years (Y)
  • Maximum size: 65 × 42 × 23 mm
Note that there are more recent sensors from plantower (PMSxxxx series) which we will be testing later.

Schauen Sie sich den Sensor von innen an

The sensor comes with a metal casing which is used to prevent from electrostatic discharge (ESD). The inside is enginered like a small dylos monitor:
Image attribution: geek-workshop.com.

- -

In terms of electronics, the PMS1003 is simple but yet very efficient. The main CPU is a Cypress CY8C4245, which a combined ARM Cortex-M0 running at 48Mhz with dedicated ADC, used to sample the output from the diode.

In terms of dust accumulation, the situation is actually not so bad since after 6 months running 24/7, the dust would only accumulated next to the air inlet, but not on the diode or laser.

Echtzeitdaten

Note: The sensor has been replaced with a new sensor on Nov. 6th 2015. We suspect that the old sensor, which was used 24/7 during 1 hour (in outdoor conditions) is not accurate anymore, either due to dust accumulation, or to decreased sensitivity of the diode to laser power. Once we have more information about this issue, we will provide our findings.

Current Dylos readings are:
  • Particules larger than 2.5 is -,
  • Particules llarger than 0.5 is -,
  • updated on - - (China time).

Current PMS1003 readings:
  • PM1 mg/m3: -,
  • PM2.5 mg/m3: -,
  • PM10 mg/m3: -,
  • updated on - - (China time).

Time series graphs

Note that on the above graph, each of the graph is plotted using a loess smoothing since the output from the PMS 1003 is quite noisy. You can move your mouse over the graph labels to see the actual output vs. the averaged values.

PM2.5 Comparison with Dylos

PM10 Comparison with Dylos




- -

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

Über Messungen zur Luftqualität und Verschmutzung

Über die Luftqualitätsstufen

- Luftqualitätswerte (AQI)Stufen zur Bewertung der Gesundheitsgefährdung
0 - 50 Gut Die Luftqualität wird als zufriedenstellend angesehen, und die Luftverschmutzung birgt wenig oder kein Risiko.
51 -100 Mäßig Luftqualität ist akzeptabel; Bei einigen Schadstoffen kann es jedoch für eine sehr kleine Anzahl von Personen, die gegenüber Luftverschmutzung ungewöhnlich empfindlich sind, zu einem mäßigen Gesundheitsrisiko kommen.
101-150 Ungesund für sensible Gruppen Mitglieder von sensiblen Gruppen können gesundheitliche Auswirkungen haben. Die breite Öffentlichkeit wird wahrscheinlich nicht betroffen sein.
151-200 Ungesund Gesundheitliche Auswirkungen sind für jeden spürbar; für sensible Gruppen besteht möglicherweise ein ernstes gesundheitliches Risiko.
201-300 Sehr Ungesund Notfallwarnung vor Gesundheitsgefahren. Die Gesamtbevölkerung ist davon wahrscheinlich betroffen.
300+ Gefährlich Gesundheitswarnung: Jeder kann ernstere gesundheitliche Auswirkungen haben

Um mehr über Luftqualität und -verschmutzung zu erfahren, gehen Sie auf die Seite Luftverschmutzung (Wikipedia) oder den AIRNow Leitfaden für Luftqualität und Ihre Gesundheit der US-amerikanischen Umweltagentur.

Sehr nützliche Gesundheitsratschläge gibt der Pekinger Arzt Richard Saint Cyr MD, www.myhealthbeijing.com in seinem Blog.


Nutzungshinweis: Alle Luftqualitätsdaten sind zum Zeitpunkt der Veröffentlichung noch nicht verifiziert, und aufgrund der Qualitätssicherung können diese Daten jederzeit ohne vorherige Ankündigung geändert werden. Das World Air Quality Index Projekt hat alle angemessenen Fähigkeiten und Sorgfalt bei der Zusammenstellung der Inhalte dieser Informationen angewandt und unter keinen Umständen, vertraglich oder anderweitig haftet das , das World Air Quality Index Projektteam oder seine Agenten wegen unerlaubter Handlung oder anderweitig für Verluste, Verletzungen oder Schäden, die direkt oder indirekt aus der Bereitstellung dieser Daten entstehen.



Einstellungen


Spracheinstellungen:


Temperature unit:
Celcius