For a complete list of all the Air Quality Sensors test on aqicn.org, check our sensor overview page.
The PMS 1003 Sensor
The PMS 1003 Sensor is a recent laser based Air Quality Sensor developped by plantower (chinese name: 攀藤 (pānténg)) and used inside a numerous number of air quality sensing devices.
It is also sometimes refered as HK 5001, or labelled under the "oneair" brand, but it is indeed developped and produced by plantower (a Shenzhen based company with office in Beijing).
Specifications
This is the specification for the PMS1003. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).
Measuring range: 0.3 to 1.0, 1.0 ~ 2.5, 2.5 to 10 microns (um)
Range: 0 ~ 500 ug / m3
counting accuracy of 50% @ 0.3um, 98% @ ≥0.5 um said the quasi-volume : 0.1 liters (L)
Response time: ≤10 seconds (s)
DC supply voltage: 5.0 volts (V)
Maximum Operating Current: 120 milliamperes (mA)
Standby current: ≤200 microamps (uA)
Operating temperature range: -20 ~ + 50 degrees Celsius (℃)
Operating humidity range: 0 ~ 99% RH
MTBF: ≥ 5 years (Y)
Maximum size: 65 × 42 × 23 mm
Note that there are more recent sensors from plantower (PMSxxxx series) which we will be testing later.
Inside look at the sensor
The sensor comes with a metal casing which is used to prevent from electrostatic discharge (ESD). The inside is enginered like a small dylos monitor:
In terms of electronics, the PMS1003 is simple but yet very efficient. The main CPU is a Cypress CY8C4245, which a combined ARM Cortex-M0 running at 48Mhz with dedicated ADC, used to sample the output from the diode.
In terms of dust accumulation, the situation is actually not so bad since after 6 months running 24/7, the dust would only accumulated next to the air inlet, but not on the diode or laser.
Real-time data
Note: The sensor has been replaced with a new sensor on Nov. 6th 2015. We suspect that the old sensor, which was used 24/7 during 1 hour (in outdoor conditions) is not accurate anymore, either due to dust accumulation, or to decreased sensitivity of the diode to laser power. Once we have more information about this issue, we will provide our findings.
Current Dylos readings are:
Particules larger than 2.5 is -,
Particules llarger than 0.5 is -,
updated on -- (China time).
Current PMS1003 readings:
PM1 mg/m3: -,
PM2.5 mg/m3: -,
PM10 mg/m3: -,
updated on -- (China time).
Time series graphs
Note that on the above graph, each of the graph is plotted using a loess smoothing since the output from the PMS 1003 is quite noisy. You can move your mouse over the graph labels to see the actual output vs. the averaged values.
PM2.5 Comparison with Dylos
PM10 Comparison with Dylos
--
For the list of all air quality sensors, check the Sensor Overview page
หากต้องการคำแนะนำด้านสุขภาพที่เป็นประโยชน์มากของแพทย์ปักกิ่ง Richard Saint Cyr MD โปรดดูบล็อกที่ www.myhealthbeijing.com
ประกาศเกี่ยวกับการใช้งาน: ข้อมูลคุณภาพอากาศทั้งหมดอาจจะยังไม่ได้รับการตรวจสอบในขณะที่มีการเผยแพร่และเนื่องจากการตรวจสอบข้อมูลเหล่านี้อาจได้รับการแก้ไขโดยไม่ต้องแจ้งให้ทราบได้ตลอดเวลา โครงการ World Air Quality Index ได้ระมัดระวังเรื่องความเหมาะสมในการรวบรวมเนื้อหาของข้อมูลนี้และภายใต้การควบคุมของทีมงานโครงการWorld Air Quality Indexหรือตัวแทนของโครงการจะรับผิดชอบต่อการทำสัญญาละเมิดหรืออื่น ๆ สำหรับการสูญเสียการบาดเจ็บหรือความเสียหายที่เกิดขึ้นโดยตรงหรือโดยอ้อมจากการจัดหาข้อมูลนี้