Publishing API for Dylos and Shinyei sensors

Note. The content on this page is outdated.
For the most recent upload API document, go to https://aqicn.org/data-feed/upload-api/

If you have a Dylos or Shinyei sensor, and you would like to publish its data on the World Air Quality Index, then this page is for you. One of the easiest solution for uploading the Dylos data is to use the ready made scripts available on github. But if you need to brew your own system, or upload data from the Shinyei sensor, then you can use the APIs described on this page.

Note that this API specification is not final, but still on-going work, so if you meet any difficulty with the integration, just contact us to get the support.


--

API Endpoint

http://sensor.aqicn.org/

API Method: Uploading data

post /sensor/upload
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • key: Sensor password - optional, only if the sensor ID is 'locked'.
  • time: Sensor time, with timezone information, in ISO 8601 format- eg 2014/10/08 18:03:45 +0800
  • location: Sensor position (latitude, longitude) - optional only if correlation with BAM sensor is requested

  • data: Array, containing all the raw readings
    • type: Sensor data type. For now, can be "dylos-0.5", "dylos-2.5", "shinyei-pdp42ns-2.5u" or "shinyei-pdp42ns-1u".
    • unit: Sensor data unit. For now, can be "pc" (particule count) or "lpo" (low pulse occupancy).
    • value: Sensor data reading. eg 94948 or 0.374

    Notes
    1. The above parameters are encapsulated within the argument 'postdata' of the post request.
    2. The LPO value must be between 0 and 1. 0 Means transparent, 1 Opaque. For more information on how to extrac the LPO from the Shinyei sensor, please refer to this page: api/shinyei.
Example:
...
Return value:
  • result: Can be either ok or error.

    In case of ok result, the returned value will contain the sensor id as well as the upload data ids (for information purpose only).
    ...

    In case of error, the returned value will contain a description (field msg) and an error code (field ecode) which can be one of the following:

    • 101: There are missing arugments from the posted data. Minimum arguments are id, time and data.
    • 102: Key is not valid - the sensor is protected by password and the provided password is not correct.
    • 103: No data posted (i.e empty array or data is not an array).
    • 104: Unit, type of value information not available from the data field.
    • 105: Sensor type is unknown.
    • 106: The field value is not numeric.
    • 107: Time string can not be decode (is it ISO 8601 complaiant?)
    • 108: SQL query failed.
    ...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/upload/" -d 'postdata={id:"dylos.test-sensor-id",time:"2014-10-16T19:20:31+08:00",data:[{type:"dylos-2.5",value:88,unit:"pc"}]}'

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:28:34 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"result":"ok","sensorID":"588","dataids":[2825275]}


API Method: Getting the raw sensor data

get /sensor/download
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • callback: Optional JsonP callback (eg "foo").
Example :
 http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo 

Return value:
...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo"

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:42:12 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"id":"dylos.test-sensor-id","data":{"dylos-0.5":[{"time":"1413458432","value":"89"}],"dylos-2.5":[{"time":"1413458432","value":"89"},{"time":"1413458431","value":"88"}]}}


Tentang Pengukuran Kualitas dan Polusi Udara:

Tentang Tingkat Kualitas Udara

- Nilai Indeks Kualitas Udara (AQI).Tingkat Kekhawatiran Kesehatan
0 - 50 Baik Kualitas udara dianggap memuaskan, dan polusi udara menimbulkan sedikit atau tanpa risiko
51 -100 Moderat Kualitas udara dapat diterima; Namun, untuk beberapa polutan mungkin ada kekhawatiran kesehatan yang moderat untuk sejumlah kecil orang yang sangat sensitif terhadap polusi udara.
101-150 Tidak Sehat untuk kelompok orang yang sensitif Anggota kelompok sensitif dapat mengalami efek kesehatan. Masyarakat umum tidak mungkin terpengaruh.
151-200 Tidak sehat Setiap orang mungkin mulai mengalami efek kesehatan; anggota kelompok sensitif dapat mengalami efek kesehatan yang lebih serius
201-300 Sangat Tidak Sehat Peringatan kesehatan untuk kondisi darurat. Seluruh penduduk lebih mungkin terpengaruh.
300+ Berbahaya Peringatan kesehatan: semua orang mungkin mengalami efek kesehatan yang lebih serius

Untuk mengetahui lebih banyak tentang Kualitas dan Polusi Udara, lihat topik Kualitas Udara di wikipedia atau panduan airnow tentang Kualitas Udara dan Kesehatan Anda .

Untuk nasihat kesehatan yang sangat berguna dari Dokter Beijing Richard Saint Cyr MD, periksa blog www.myhealthbeijing.com .


Pemberitahuan Penggunaan: Semua data Kualitas Udara tidak divalidasi pada saat publikasi, dan demi jaminan kualitas maka data ini dapat diubah, tanpa pemberitahuan, kapan saja. Proyek Indeks Kualitas Udara Dunia telah menerapkan semua kemampuan dan kepedulian yang cukup dalam mengumpulkan isi informasi ini dan dalam keadaan apa pun World Air Quality Index tim proyek atau agennya bertanggung jawab dalam kontrak, gugatan atau jika ada kerugian, cedera atau kerusakan yang timbul secara langsung atau tidak langsung dari pasokan data ini.



Settings


Language Settings:


Temperature unit:
Celcius