The PMS 3003 Sensor

The PMS 3003 Sensor is the third generation evolution of the PMS1003 developped by plantower (chinese name: 攀藤 (pānténg).

規格

This is the specification for the PMS3003. One should not consider all those values for granted as there is quite often a big difference between what is said to be possible and what is actually possible (and this is why we are setting up all our experiments).
  • Parameters :Index  (Unit )
  • Measuring range :0.3 to 1.0 ; 1.0 to 2.5 ; 2.5 to 10  (mm)
  • Counting efficiency :50%@0.3um 98% @> = 0.5 um 
  • Response time :≤ 10  sec
  • DC supply voltage :5 V
  • Operating current :120  mA
  • Standby Current :≤ 200  µA
  • Data interface level :L <0.8 @ 3.3 H> 2.7@3.3  V
  • Operating temperature range :-20 ~ + 50  °C
  • Operating humidity range :0 to 99% 
  • MTBF :≥ 3  Year
  • Size :65 × 42 × 23  mm

看看感測器的內部

Compared to the PMS1003, the PMS3003 is just a mechanical size reduction - the electronic is the same. In the former mechanisms, there used to be a mechanical air chamber, which is now removed a replaced by a simple hole over the diode. This is probably because their attempt to imitate Dylos' pressure drop patent proved to be inefficient in the first generation.
The electronic components are the same, at least for the main CPU, a Cypress CY8C4245. That's a bit disapointing since a higher frequency CPU/ADC could help for the advanced processing so much needed for better understand the air quality. Hopefully this is something we will find in the 7th generation sensor, which is comming quite soon. Stay tunned!
Playing arround with this sensor is quite simple as it exports a serial interface. The pin-out in the following:
  • PIN1  :VCC :Power Supply (5V).
  • PIN2  :GND :Ground.
  • PIN3  :SET :Standby mode (when 0), operating mode (when 1)
  • PIN4  :RXD :Serial receive / TTL level @ 3.3V.
  • PIN5  :TXD :Serial transmit / TTL level @ 3.3V.
  • PIN6  :RESET :Module reset / TTL level @ 3.3V.
  • PIN7,8 :NC :Not connected.

即時數據

There are two co-located PMS3003 sensors (both are outside). First PMS 3003 outdoor readings are:
  • PM1 count: -,
  • PM2.5 count: -,
  • PM10 count: -,
  • updated on - - (China time).
Second PMS 3003 outdoor readings are:
  • PM1 count: -,
  • PM2.5 count: -,
  • PM10 count: -,
  • updated on - - (China time).

Time series graphs




- -

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

關於空氣質量與空氣污染指數

本網站採用的污染指數和顏色與EPA是完全相同的。 EPA的指數可以從 AirNow上查到

空气质量指数 空气质量指数级别(状况)及表示颜色 对健康影响情况 建议采取的措施
0 - 50 一级(优) 空气质量令人满意,基本无空气污染 各类人群可正常活动
51 -100 二级(良) 空气质量可接受,但某些污染物可能对极少数异常敏感人群健康有较弱影响 极少数异常敏感人群应减少户外活动
101-150 三级(轻度污染) 易感人群症状有轻度加剧,健康人群出现刺激症状 儿童、老年人及心脏病、呼吸系统疾病患者应减少长时间、高强度的户外锻炼
151-200 四级(中度污染) 进一步加剧易感人群症状,可能对健康人群心脏、呼吸系统有影响 儿童、老年人及心脏病、呼吸系统疾病患者避免长时间、高强度的户外锻炼,一般人群适量减少户外运动
201-300 五级(重度污染) 心脏病和肺病患者症状显著加剧,运动耐受力降低,健康人群普遍出现症状 儿童、老年人及心脏病、肺病患者应停留在室内,停止户外运动,一般人群减少户外运动
300+ 六级(严重污染) 健康人群运动耐受力降低,有明显强烈症状,提前出现某些疾病 儿童、老年人和病人应停留在室内,避免体力消耗,一般人群避免户外活动
(参考详见 http://zh.wikipedia.org/wiki/空气质量指数)

如果你想了解更多有關空氣質量與污染,詳見維基百科或者 AirNow

有關健康建議詳​​見北京的Richard Saint Cyr MD醫生的博客:www.myhealthbeijing.com


注意事項: 所有空氣品質數據在發佈時均未經驗證,且為了確保資料準確性,這些數據可能隨時被修改,恕不另行通知。 世界空氣品質指數專案在編制這些訊息內容時已經謹慎的運用了所有適當的技巧,在任何情況下世界空氣品質指數 在任何情況下,世界空氣品質指數專案團隊或其代理人均不對因提供此數據而直接或間接引起的任何損失、傷害或損害來承擔契約、侵權或其他責任。



設定


選擇語言:


Temperature unit:
Celcius