The Plantower PMS5003 and PMS7003 Air Quality Sensor experiment

แบ่งปัน: aqicn.org/sensor/pms5003-7003/th/
For a complete list of all the Air Quality Sensors test on aqicn.org, check our sensor overview page.



PMS5003
PMS7003

Plantower PMS 5003 and PMS 7003 Sensor

The PMS 7003 and PMS 5003 sensors are the 7th resp 5th generation of the PMSx003 series developed by Plantower (chinese name 攀藤).

Experiment Setup

For this experiment, 3 PMS 7003 and 3 PMS 5003 are co-located together. The objective is to understand the accuracy of individual sensor readings, and potential level of error induced by the lack of efficient calibration of low-cost sensors .

For each sensor (PMS5003 and PMS7003), there are 3 sensors (identified as PMSx003 #1, #2 and #3) running in alternation over a period of 3 minute. For each minute, only the last 30 seconds data is collected, as the first 30 seconds as kept to let the sensor stabilize its output.

There is additional PMS5003 sensor (number #4 ): It is a used (old) sensors which has been running in continuous mode for several months outdoor. The objective for this sensor is to understand if the accuracy decreases with the age (during to the laser or fan wearing off).

Specification sheets: PMS5003.pdf and PMS7003.pdf.

Note that the PMSx data from the Sensor comes in two flavors: '标准颗粒物' (Standard Particles or CF-1, bytes 4-9) and '大气环境下' (Atmospheric Environment, bytes 10-15). It is the second one which we use for this experiments (Thanks to Bart for the clarification).

Sensor tear-down

The following pictures are taken from a PMS5003 running for several months outdoor in continuous mode.


The good news is that Plantower managed to do a pretty good mechanical design which prevents dust accumulation on the front-side of the PCB (see image A on the right), where laser and diode are mounted. Compared to the dust accumulation on the Dylos, that guarantees a much better lifetime and data accuracy over time.

In terms of electrical and electronic components, the PMS5003 is not quite different from the initial PMS1003 desing. The CPU is still a Cypress CY8C4245, which a combined ARM Cortex-M0 running at 48Mhz with dedicated ADC, used to sample the output from the diode.

Real-time data

db stands for dust bin and is measured in counts per minute. For instance, db2.5-um represents the count of particles with an aerodynamic diameter below 2.5 µm;

Time series for Meteorological Conditions

Meteorological conditions, and especially the Relative Humidity (RH) is needed as high RH might have a direct impact on the size of the particle size detected by the laser. For BAM sensors, there is actually a requirement for constant humidity.

Above graph is based on CWOP station EW2754. Below table is based on the real-time readings from our GAIA A12 station

Time series for Particulate Matter

Note that the first 3 time-series graphs are showing the values using AQI (and not raw mg/m3). The AQI is based on the US EPA breakpoints. For PM1, the PM2.5 breakpoints are used.

For the particulate matter graphs, the reference BAM measurements from the neighbor stations are shown, but not taken into account for the deviation plot ~ the aim of this experiments is to understand the deviation in between sensors of the same type (eg PMS) and not in between sensors using different technologies (eg Laser Counter vs Beta Attenuation).

The deviation plots below each time-series is computed as the difference between the minimum (in blue) resp. maximum (in red) value and the average reading for each 5 minute period block. The X axis is showing the average value, and the Y axis the difference between min/max and average. For the first 3 time-series graphs, the difference is expressed in AQI: This way, it is easy to asses the potential error in AQI value of those low-cost sensors.

Comparison between Std. Particle (标准颗粒物) and Std. Atmosphere (大气环境下)

CF1 refers to Std. Particle (标准颗粒物). SAT refers to Std. Atmosphere (大气环境下).

The graphs below shows the correlation for the CF1 (X, absyss) and the ratio CF1/SAT (Y, ordinate), for the PM2.5 and PM10 data.


The almost too perfect correlation between approx. 30 mg to 100 mg for PM2.5 / PMS5003, (40mg to 150 for PM10) does not sound too scientific...

cf1<30 ⇒ sat=cf1
cf1>100 ⇒ sat = cf1 * 2/3
cf1 in ∈ [30;100] ⇒ sat = 30 + cf1 * (cf1-30)/70 * 2/3

Note: Thanks to Bart for the comment on `CF1>30 ⇒ SAT < CF1`
The formula has been updated with correct ratio (2/3)

One interesting question is whether is CF-1/SAT ratio is part of the calibration process done by Plantower; At least, for PM2.5 the upper threshold for PMS7003 and PMS5003 are different (85 for the first, and 100 for the second). When sufficient data is available, this page will be updated with the answer...

Correlation between PM10 and PM2.5

Refering to the experiment on PM10 vs PM2.5, the question is weather the PMS sensor is able to correctly detect the particules. The graph below show the correlation between PM10 vs PM2.5 CF-1 readings for the past 10 days.


For now, the correlation seems perfectly linear, but as soon as the next PM10 pollution event comes, the graph will be able to confirm the efficiency of bin size detection.

Moreover, one interesting pattern to check for is the non-linear curve, which can be seen on the Dylos sensor. This curved pattern is due to the sensor not beeing able to properly detect the different particles bins, caused by a too high number of particles 'obstructing' the diode. For now, the Air Pollution is too low to detect this phenomenon, but as soon as winter arrives, the data will confirm the existence of this pattern or not.

Time series for Particulate Matter (Indoor setup)

There are 2 additional indoor PMS5003 sensors:
The graphs below are expressed in AQI units.
And this is for the meteorological indoor sensor



- -

For the list of all air quality sensors, check the Sensor Overview page

Read or publish comments (they rely on Disqus)

เกี่ยวกับการตรวจวัดคุณภาพอากาศและมลพิษ:

เกี่ยวกับระดับคุณภาพอากาศ

- ค่าดัชนีคุณภาพอากาศ (AQI)ระดับความกังวลเรื่องสุขภาพ
0 - 50 ดี คุณภาพอากาศถือว่าเป็นที่น่าพอใจและมลพิษทางอากาศทำให้เกิดความเสี่ยงเพียงเล็กน้อยหรือไม่มีเลย
51 -100 ปานกลาง คุณภาพอากาศเป็นที่ยอมรับได้ อย่างไรก็ตามสำหรับสารมลพิษบางอย่างอาจต้องระวังในกลุ่มผู้ที่แพ้ฝุ่นละอองและสารเคมีได้ง่าย
101-150 ไม่ดีต่อสุขภาพ สำหรับ กลุ่มที่ไวต่อมลพิษทางอากาศ หรือกลุ่มที่แพ้อากาศง่าย อาจมีผลกระทบต่อสุขภาพของประชาชนกลุ่มเสี่ยง ส่วนประชาชนทั่วไปอาจไม่ได้รับผลกระทบ
151-200 มีผลกระทบต่อสุขภาพ เราทุกคนอาจเริ่มรู้สึกถึงผลกระทบต่อสุขภาพ กลุ่มคนที่มีความเสี่ยงสูงอาจได้รับผลกระทบด้านสุขภาพที่รุนแรงขึ้น
201-300 อันตรายต่อสุขภาพเป็นอย่างมาก คำเตือนด้านสุขภาพในภาวะฉุกเฉิน ประชากรทั้งหมดมีแนวโน้มที่จะได้รับผลกระทบมากขึ้น
300+ เสี่ยงอันตราย การแจ้งเตือนด้านสุขภาพ: ทุกคนอาจได้รับผลกระทบด้านสุขภาพที่รุนแรงขึ้น

หากต้องการทราบข้อมูลเพิ่มเติมเกี่ยวกับคุณภาพอากาศและมลพิษ โปรดดู หัวข้อคุณภาพอากาศในวิกิพีเดีย หรือ คู่มือ airnow เกี่ยวกับคุณภาพอากาศและสุขภาพของคุณ

หากต้องการคำแนะนำด้านสุขภาพที่เป็นประโยชน์มากของแพทย์ปักกิ่ง Richard Saint Cyr MD โปรดดูบล็อกที่ www.myhealthbeijing.com


ประกาศเกี่ยวกับการใช้งาน: ข้อมูลคุณภาพอากาศทั้งหมดอาจจะยังไม่ได้รับการตรวจสอบในขณะที่มีการเผยแพร่และเนื่องจากการตรวจสอบข้อมูลเหล่านี้อาจได้รับการแก้ไขโดยไม่ต้องแจ้งให้ทราบได้ตลอดเวลา โครงการ World Air Quality Index ได้ระมัดระวังเรื่องความเหมาะสมในการรวบรวมเนื้อหาของข้อมูลนี้และภายใต้การควบคุมของทีมงานโครงการWorld Air Quality Indexหรือตัวแทนของโครงการจะรับผิดชอบต่อการทำสัญญาละเมิดหรืออื่น ๆ สำหรับการสูญเสียการบาดเจ็บหรือความเสียหายที่เกิดขึ้นโดยตรงหรือโดยอ้อมจากการจัดหาข้อมูลนี้



Settings


Language Settings:


Temperature unit:
Celcius