If you have a Dylos or Shinyei sensor, and you would like to publish its data on the World Air Quality Index, then this page is for you. One of the easiest solution for uploading the Dylos data is to use the ready made scripts available on github. But if you need to brew your own system, or upload data from the Shinyei sensor, then you can use the APIs described on this page.

Note that this API specification is not final, but still on-going work, so if you meet any difficulty with the integration, just contact us to get the support.


--

API Endpoint

http://sensor.aqicn.org/

API Method: Uploading data

post /sensor/upload
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • key: Sensor password - optional, only if the sensor ID is 'locked'.
  • time: Sensor time, with timezone information, in ISO 8601 format- eg 2014/10/08 18:03:45 +0800
  • location: Sensor position (latitude, longitude) - optional only if correlation with BAM sensor is requested

  • data: Array, containing all the raw readings
    • type: Sensor data type. For now, can be "dylos-0.5", "dylos-2.5", "shinyei-pdp42ns-2.5u" or "shinyei-pdp42ns-1u".
    • unit: Sensor data unit. For now, can be "pc" (particule count) or "lpo" (low pulse occupancy).
    • value: Sensor data reading. eg 94948 or 0.374

    Notes
    1. The above parameters are encapsulated within the argument 'postdata' of the post request.
    2. The LPO value must be between 0 and 1. 0 Means transparent, 1 Opaque. For more information on how to extrac the LPO from the Shinyei sensor, please refer to this page: api/shinyei.
Example:
...
Return value:
  • result: Can be either ok or error.

    In case of ok result, the returned value will contain the sensor id as well as the upload data ids (for information purpose only).
    ...

    In case of error, the returned value will contain a description (field msg) and an error code (field ecode) which can be one of the following:

    • 101: There are missing arugments from the posted data. Minimum arguments are id, time and data.
    • 102: Key is not valid - the sensor is protected by password and the provided password is not correct.
    • 103: No data posted (i.e empty array or data is not an array).
    • 104: Unit, type of value information not available from the data field.
    • 105: Sensor type is unknown.
    • 106: The field value is not numeric.
    • 107: Time string can not be decode (is it ISO 8601 complaiant?)
    • 108: SQL query failed.
    ...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/upload/" -d 'postdata={id:"dylos.test-sensor-id",time:"2014-10-16T19:20:31+08:00",data:[{type:"dylos-2.5",value:88,unit:"pc"}]}'

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:28:34 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"result":"ok","sensorID":"588","dataids":[2825275]}


API Method: Getting the raw sensor data

get /sensor/download
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • callback: Optional JsonP callback (eg "foo").
Example :
 http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo 

Return value:
...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo"

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:42:12 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"id":"dylos.test-sensor-id","data":{"dylos-0.5":[{"time":"1413458432","value":"89"}],"dylos-2.5":[{"time":"1413458432","value":"89"},{"time":"1413458431","value":"88"}]}}


درباره اندازه گیری کیفیت و آلودگی هوا:

درباره سطوح کیفیت هوا

- مقادیر شاخص کیفیت هوا (AQI).سطوح نگرانی سلامت
0 - 50 خوب کیفیت هوا رضایتبخش است و آلودگی هوا کم یا بدون خطر است
51 -100 در حد متوسط کیفیت هوا قابل قبول است با این حال، برای بعضی از آلاینده ها ممکن است نگرانی سلامت متوسط برای تعداد بسیار کمی از افرادی که به طور غیر منتظره ای نسبت به آلودگی هوا حساس هستند، وجود داشته باشد.
101-150 ناسالم برای گروه های حساس سلامتی گروه های حساس ممکن است تحت تاثیر قرار بگیرد.عموم مردم احتمالا تحت تاثیر قرار نخواهند گرفت.
151-200 ناسالم همه ممکن است اثرات آلودگی بر سلامتیشان را احساس کنند؛ اعضای گروه های حساس ممکن است اثرات منفی جدی تری بر سلامتی شان احساس کنند.
201-300 خیلی ناسالم هشدارهای بهداشتی در شرایط اضطراری. کل جمعیت بیشتر احتمال دارد تحت تأثیر قرار گیرد.
300+ خطرناک هشدار سلامت: هرکس ممکن است اثرات جدی سلامتی را تجربه کند

برای اطلاعات بیشتر در مورد کیفیت هوا و آلودگی، موضوع کیفیت هوا در ویکی‌پدیا یا راهنمای airnow برای کیفیت هوا و سلامت شما را بررسی کنید.

برای توصیه های بهداشتی بسیار مفید دکتر پکن ریچارد سنت سیر، وبلاگ www.myhealthbeijing.com را بررسی کنید.


اطلاعیه درمورد شرایط استفاده: تمام اطلاعات کیفیت هوا در زمان انتشار تایید نشده است و با توجه به عدم اطمینان از کیفیت این اطلاعات ممکن است بدون اطلاع قبلی در هر زمانی اصلاح شود. پروژه شاخص کیفیت جهانی هوا با استفاده از تمام مهارت ها و مراقبت های معقول در انتشار محتویات این اطلاعات، تحت هیچ شرایطی شاخص کیفیت جهانی هوا تیم پروژه یا نمایندگان آن برای هر گونه از دست دادن، آسیب یا آسیب ناشی از عرضه اطلاعات مسئولیتی را قبول نمی‌کنند.



Settings


Language Settings:


Temperature unit:
Celcius