Mantenimiento del experimento Dylos Air Particule Conter.

Posted on October 21st 2013
Share: aqicn.org/faq/2013-10-21/dylos-air-particule-conter-experiment-maintenance/es/



Note: this article was written in 2013. While the Dylos monitor is still a good product, there is nowdays much better and affordable monitoring products, so we do not recommend purchasing the Dylos product anymore.
You can for instance check the GAIA air quality monitoring stations product range from ES Labs.


The Dylos Air Particle Counter experiment is still going-on, and has been on for now 50 days. So, last weekend, as the air pollution in Beijing was getting really low - thanks to strong north winds, we used this time as an opportunity to perform a maintenance break... on the Dylos monitor itself.

The reason is that, even if the Dylos monitor is definitely well designed and engineered equipment (we do mean it), it maybe not be so well conceived to subsist Beijing's tough episodic Air Pollution.

It all started after noticing that the correlation graphs between the Dylos and BAM monitor tend to show some systematic signs of leveling beyond 38,000 particles (≥0.5µ). This kind of saturation symptom can be the consequence of internal air inflow bottleneck, which can be caused by "saturated" air channels. During times of heavy pollution, this phenomenon is totally normal due to the large amount of particulate matter having to go through the air channel.

So, no surprise, after opening the Dylos monitor, we confirmed that the internal air channels are definitely saturated, by an accumulation of dust during the last 50 days:

 
-Beijing dust impact on the Dylos air particle counter internal structure-


The result of cleaning the internal structure, using a fine brush, would produce an astonishing amount of dust - and this, just after 50 days of outdoor experimentation. Just think that this is what you are breathing...


-The real Beijing dust... the one Beijiners breathe during heavy pollution day!-


Actually, having to perform such cleaning and maintenance on the Dylos equipment is not a surprise, since even the very expensive BAM equipment requires monthly maintenance by skilled operators.


--

The following part has been added 10 days after the initial post was published:

It is now 10 days since the cleaning has been done, and the situation has definitely improved for the correlation between BAM and Dylos. From the graph below, which shows the measurements before and after the cleaning, the zone indicated with number (2) shows a very good similarity (correlation) between BAM and Dylos. But, under condition of heavy pollution, there are still consistent signs of leveling (deviation in measurement), as highlighted with zone number (1) and (3). The deviation seems however less worse after the cleaning (zone (3)) than before (zone (1)). We are contacting the Dylos company, to consult them on this leveling phenomenon, and will update this post later.


(Click on the picture to open the real time version)

--



Click here to see all the FAQ entries
Read or publish comments (they rely on Disqus)

Acerca de la calidad del aire y la medición de la contaminación:

Acerca de los niveles de calidad del aire

ICACalidad del AireProteja su Salud
0 - 50BuenaNo se anticipan impactos a la salud cuando la calidad del aire se encuentra en este intervalo.
51 -100ModeradaLas personas extraordinariamente sensitivas deben considerar limitación de los esfuerzos físicos excesivos y prolongados al aire libre.
101-150Dañina a la Salud de los Grupos SensitivosLos niños y adultos activos, y personas con enfermedades respiratorias tales como el asma, deben evitar los esfuerzos físicos excesivos y prolongados al aire libre.
151-200Dañina a la SaludLos niños y adultos activos, y personas con enfermedades respiratorias tales como el asma, deben evitar los esfuerzos excesivos prolongados al aire libre; las demás personas, especialmente los niños, deben limitar los esfuerzos físicos excesivos y prolongados al aire libre.
201-300Muy Dañina a la SaludLos niños y adultos activos, y personas con enfermedades respiratorias tales como el asma, deben evitar todos los esfuerzos excesivos al aire libre; las demás personas, especialmente los niños, deben limitar los esfuerzos físicos excesivos al aire libre.
300+Arriesgado

Para saber más sobre la calidad del aire y la contaminación, comprobar la tema Calidad wikipedia Air o Guía airnow a la calidad del aire y su salud .

Para obtener consejos de salud muy útiles de Beijing doctor Richard Saint Cyr MD, compruebe www.myhealthbeijing.com blog.


Aviso de uso: Todos los datos de Calidad del aire no están validados en el momento de la publicación, y debido a la garantía de calidad, estos datos pueden modificarse, sin previo aviso, en cualquier momento. El proyecto World Air Quality Index ha ejercido todas las habilidades y cuidados razonables para compilar el contenido de esta información y en ningún caso el World Air Quality Index o el equipo del proyecto será responsable en el contrato, agravio o de otra manera por cualquier pérdida, lesión o daño que surja directa o indirectamente del suministro de esta información.



Configuración


Configuración de idioma:


Temperature unit:
Celcius