Publishing API for Dylos and Shinyei sensors

Note. The content on this page is outdated.
For the most recent upload API document, go to https://aqicn.org/data-feed/upload-api/

If you have a Dylos or Shinyei sensor, and you would like to publish its data on the World Air Quality Index, then this page is for you. One of the easiest solution for uploading the Dylos data is to use the ready made scripts available on github. But if you need to brew your own system, or upload data from the Shinyei sensor, then you can use the APIs described on this page.

Note that this API specification is not final, but still on-going work, so if you meet any difficulty with the integration, just contact us to get the support.


--

API Endpoint

http://sensor.aqicn.org/

API Method: Uploading data

post /sensor/upload
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • key: Sensor password - optional, only if the sensor ID is 'locked'.
  • time: Sensor time, with timezone information, in ISO 8601 format- eg 2014/10/08 18:03:45 +0800
  • location: Sensor position (latitude, longitude) - optional only if correlation with BAM sensor is requested

  • data: Array, containing all the raw readings
    • type: Sensor data type. For now, can be "dylos-0.5", "dylos-2.5", "shinyei-pdp42ns-2.5u" or "shinyei-pdp42ns-1u".
    • unit: Sensor data unit. For now, can be "pc" (particule count) or "lpo" (low pulse occupancy).
    • value: Sensor data reading. eg 94948 or 0.374

    Notes
    1. The above parameters are encapsulated within the argument 'postdata' of the post request.
    2. The LPO value must be between 0 and 1. 0 Means transparent, 1 Opaque. For more information on how to extrac the LPO from the Shinyei sensor, please refer to this page: api/shinyei.
Example:
...
Return value:
  • result: Can be either ok or error.

    In case of ok result, the returned value will contain the sensor id as well as the upload data ids (for information purpose only).
    ...

    In case of error, the returned value will contain a description (field msg) and an error code (field ecode) which can be one of the following:

    • 101: There are missing arugments from the posted data. Minimum arguments are id, time and data.
    • 102: Key is not valid - the sensor is protected by password and the provided password is not correct.
    • 103: No data posted (i.e empty array or data is not an array).
    • 104: Unit, type of value information not available from the data field.
    • 105: Sensor type is unknown.
    • 106: The field value is not numeric.
    • 107: Time string can not be decode (is it ISO 8601 complaiant?)
    • 108: SQL query failed.
    ...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/upload/" -d 'postdata={id:"dylos.test-sensor-id",time:"2014-10-16T19:20:31+08:00",data:[{type:"dylos-2.5",value:88,unit:"pc"}]}'

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:28:34 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"result":"ok","sensorID":"588","dataids":[2825275]}


API Method: Getting the raw sensor data

get /sensor/download
Parameters
  • id: Sensor ID, eg dylos.test-sensor-id
  • callback: Optional JsonP callback (eg "foo").
Example :
 http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo 

Return value:
...

Example

 $ curl -i "http://sensor.aqicn.org/sensor/download/?id=dylos.test-sensor-id&callback=foo"

HTTP/1.1 200 OK
Date: Sun, 09 Nov 2014 08:42:12 GMT
Server: Apache/2.2.15 (CentOS)
X-Powered-By: PHP/5.3.3
Vary: Accept-Encoding
Connection: close
Transfer-Encoding: chunked
Content-Type: text/json; charset=utf-8

{"id":"dylos.test-sensor-id","data":{"dylos-0.5":[{"time":"1413458432","value":"89"}],"dylos-2.5":[{"time":"1413458432","value":"89"},{"time":"1413458431","value":"88"}]}}


O pomiarach jakości powietrza i zanieczyszczeń:

O Poziomach Jakości Powietrza

- Wartości Indeksu Jakości Powietrza (AQI)Poziomy zagrożenia zdrowia
0 - 50 Dobra 0-50: Dobra - Jakość powietrza jest uznawana za zadowalającą, a zanieczyszczenie powietrza stanowi niewielkie ryzyko lub jego brak.
51 -100 Średnia 50-100: Średnia - Jakość powietrza jest dopuszczalna; jednak niektóre zanieczyszczenia mogą być umiarkowanie szkodliwe dla bardzo małej liczby osób, które są niezwykle wrażliwe na zanieczyszczenie powietrza.
101-150 Niezdrowa dla osób wrażliwych 100-150: Niezdrowe dla wrażliwych osób - u osób wrażliwych mogą wystąpić negatywne skutki dla zdrowia. Większość populacji może nie odczuwać negatywnych objawów.
151-200 Niezdrowa 150-200: Niezdrowe - Każdy może zacząć doświadczać negatywnych skutków zdrowotnych; U osób wrażliwych mogą wystąpić poważniejsze skutki zdrowotne.
201-300 Bardzo niezdrowa 200-300: Bardzo niezdrowe - Ostrzeżenie zdrowotne, poziom alarmowy. Bardzo prawdopodobny negatywny wpływ na całą populację.
300+ Zagrożenie dla życia 300 : Niebezpieczny - Alarm Zdrowotny: każdy może doświadczyć poważniejszych skutków zdrowotnych.

Aby dowiedzieć się więcej na temat jakości powietrza i zanieczyszczenia, sprawdź w wikipedii temat "jakość powietrza" lub nasz poradnik o jakości powietrza i jego wpływie na Twoje zdrowie.

Więcej przydatnych informacji zdrowotnych na blogu doktora Richarda Sainta z Pekinu: www.myhealthbeijing.com .


Uwaga dotycząca użytkowania: Wszystkie dane dotyczące jakości powietrza mogą być nieważne w chwili publikacji, a w celu zapewnienia jakości dane te mogą być w dowolnym momencie zmieniane bez powiadomienia. Projekt World Air Quality Index wykorzystuje wszystkie przydatne umiejętności, dba o rzetelność przy kompilowaniu treści tych informacji, ale w żadnym wypadku zespół projektowy World Air Quality Index lub jego agenci nie są odpowiedzialni za umowę, delikt lub w inny sposób za jakiekolwiek straty, obrażenia lub szkody wynikające bezpośrednio lub pośrednio z dostarczania tych danych.



Ustawienia


Ustawienia Języka:


Temperature unit:
Celcius